Tevet LLC
Category >> Oscilloscope >> DSO6014L, DSO6054L, DSO6104L
Brand New Test Equipment

Complete listing for Agilent products

Agilent DSO6014L, DSO6054L, DSO6104L InfiniiVision Oscilloscopes


Agilent DSO6014L, DSO6054L, DSO6104L InfiniiVision Oscilloscopes
Click for Larger Image
  • Low profile, high density 1U (4.45 cm, 1.75 inches) package
  • LXI class C compliant
  • 100 MHz, 500 MHz and 1 GHz analog bandwidth
  • Up to 4 GSa/s sample rate
  • 8 Mpts MegaZoom III deep memory now standard
  • Full-scale connectivity – Standard USB, LAN, GPIB interface with XGA video output
  • 8-bit vertical resolution (extensible to 12 bits)
  • Mixed signal analysis option supporting integrated 4-scope and 16-logic channels
  • Built-in Web browser control
  • Optional secure environment mode
  • IVI-COM driver
  • 100% software compatible with 6000A Series portable oscilloscopes

Low-profile, high-density package saves rack space
The 6000L Series oscilloscopes provide up to 1-GHz bandwidth in a space-saving 1U-high 19-inch wide package so it saves your valuable rack space. The oscilloscopes have side and rear air vents (no top or bottom air vents) so other instruments can be mounted directly above or below them. Rack mount brackets and rack rails are standard with every unit.

LXI class C compliant
LAN eXtensions for Instrumentation (LXI) is the architecture for test systems that’s based on proven, widely used standards such as Ethernet. By specifying the interaction of those standards, LXI enables fast, efficient, cost-effective creation and reconfiguration of test systems. The 6000L Series oscilloscopes are fully LXI class C compliant. The 6000L Series oscilloscopes follow specified LAN protocols, and adhere to LXI requirements such as a built-in Web control server, IVI driver software, and more.

Easy system integration and configuration
To simplify system development, the 6000L Series oscilloscopes come standard with an IVI-COM (Interchangeable Virtual Instruments) driver, and they support easy-to-use SCPI commands. The standard Agilent I/O Library Suite makes it easy to configure and integrate instruments into your system – even if your system includes instruments from other vendors.

Built-in Web control
The built-in Web server provides remote access and control of the instrument via a standard Java™-enabled Web browser on your computer. You can communicate with the scope over the scope’s built-in LAN interface. Using the Web browser you can set up measurements, monitor waveforms, capture screen images and operate the scope remotely. Through the remote front panel you have access to the built-in help system that is available in eleven languages. Simply right click on the soft keys to see help for that function. You can also send SCPI commands over the LAN to control your scope. Wherever you are, your 6000L Series scope is as close as the nearest Web browser.

Mixed signal analysis option
If you work with both analog and digital circuitry, the Agilent 6000L Series oscilloscope can help you see more signal activity in your designs. You can upgrade the 6000L Series oscilloscope to a 4 scope +16 logic timing channel mixed signal oscilloscope (MSO). Both the MSO and the 4-channel DSO models are optimized with the capabilities you need for verifying and debugging designs that include embedded system components. With the MSO you can trigger on any combination of its scope and logic channels.

Easy transition from 6000A to 6000L
One of the biggest challenges in a new product’s life cycle is the transition of its test system from development to manufacturing. With LXI, the transition can be achieved much more easily and cost effectively than with cardcage-based systems. Engineers can use the LXI class C compliant 6000A Series portable oscilloscope during the R&D phase, using the display, keypad and knobs to quickly access a wealth of measurement capabilities. When your product moves to manufacturing, you can use a system-optimized 6000L Series LXI oscilloscope without a display. Because the 6000A and 6000L are 100% software compatible, your manufacturing system can use the software and test routines developed in R&D without any modification, while you save cost and rack space by moving from a standard benchtop oscilloscope to a 1U high oscilloscope without a display.

Agilent InfiniiVision Oscilloscope Probe Selection Guide >>

Extended Warranty Options:
Advantage Service Pack; Warranty Extension 3 to 5 years

DSO6014L R1602C
DSO6054L R1602D
DSO6104L R1602E


PRICING INFORMATION

Agilent DSO6014L 100 MHz, 4 Channel LXI Oscilloscope
 
TEVET Price $5,553
spacer
Agilent DSO6054L 500 MHz, 4 Channel LXI Oscilloscope
 
TEVET Price $11,685
spacer
Agilent DSO6104L 1 GHz, 4 Channel LXI Oscilloscope
 
TEVET Price $14,063
spacer

OPTIONS & ACCESSORIES

DSO6000L-8MH 8Mpts Memory DSO6104L/DSO6054L Scopes
8M Memory now standard 
 TEVET Price $0
spacer
DSO6000L-8ML 8Mpts Memory DSO6014L Scopes
8M Memory now standard 
 TEVET Price $0
spacer
N5427A (Opt. SEC) Secure ID
Provides the highest level of security by ensuring that internal non-volatile memory is clear of all setup and trace settings 
 TEVET Price $552
spacer
N2914A MSO upgrade, for 601x/603x
Includes a 54620-68701 logic cable kit and an upgrade license to activate the MSO features. 
 TEVET Price $1,887
spacer
N2915A MSO upgrade, for 605x/610x
Includes a 54620-68701 logic cable kit and an upgrade license to activate the MSO features. 
 TEVET Price $3,219
spacer
N5406A/001 FPGA Dynamic Probe for Xilinx
Oscilloscope Locked License 
 TEVET Price $1,700
spacer
N5406A/002 FPGA Dynamic Probe for Xilinx
PC Locked License 
 TEVET Price $1,700
spacer
N5423A (Opt. LSS) I2C and SPI Triggering & Decode
For InfiniiVision 4-channel oscilloscopes only. 
 TEVET Price $1,500
spacer
N5424A (Opt. AMS) CAN/LIN Automotive Triggering and Decode
For InfiniiVision 4-channel oscilloscopes only. 
 TEVET Price $1,500
spacer
N5432C (Opt. FLX) FlexRay Measurements
For 4-channel InfiniiVision models only. 
 TEVET Price $4,500
spacer
N5434A/001 FPGA Dynamic Probe, Altera
Oscilloscope Locked License 
 TEVET Price $1,700
spacer
N5434A/002 FPGA Dynamic Probe, Altera
PC Locked License 
 TEVET Price $1,700
spacer
N5454A (Opt. SGM) Segmented Memory
 
 TEVET Price $1,500
spacer
N5455A (Opt. LMT) Mask/Waveform Limit Test
 
 TEVET Price $750
spacer
N5457A (Opt. 232) RS-232/UART Triggering and Decode
For InfiniiVision 4-channel oscilloscopes only. 
 TEVET Price $1,500
spacer
N5466A InfiniiVision Firmware Upgrade
Includes Measurement Statistics and Tracking Cursor features and Version 5.2 bug fixes/changes. For scopes shipped prior to January 2009. 
 TEVET Price $115
spacer
N5468A (Opt. SND) I2S Triggering and Decode Option
For InfiniiVision 4-channel oscilloscopes only. 
 TEVET Price $1,500
spacer
N5469A (Opt. 553) MIL-STD 1553 Triggering and Decode
 
 TEVET Price $1,500
spacer